top of page

Automotive Paint Spraying Process

INTRODUCTION


Paint spraying within automotive body shops presents one of the highest fire and explosion hazards encountered within motor trade occupancies. The combination of flammable liquids, volatile solvent vapours, combustible overspray deposits, ignition sources and heated drying processes creates the potential for significant property damage and serious injury.

 

While modern water-based paints have reduced solvent content, many automotive refinishing processes continue to utilise flammable thinners, cleaners, hardeners and polyurethane clear lacquers. Importantly, water-based coatings can still generate combustible overspray residues and present fire hazards during spraying and curing operations.

 

MATERIAL STORAGE AREAS

 

Material storage areas contain a combination of flammable and non-flammable liquids, and typically hold a large fire load.

 

Storage controls should apply not only to paints and thinners but also to all associated refinishing materials, including primers, hardeners, catalysts, cleaning agents, degreasers, aerosols and waste products, as these can contribute significantly to the overall fire, explosion and environmental risk presented by the operation. Controls should include:

 

  • Segregated flammable liquid storage.

  • Quantities restricted to operational needs.

  • Separation from ignition sources.

  • Good stock control and housekeeping.

  • Fire-resisting construction for dedicated stores where significant quantities are held.

  • Spill containment provisions.

 

PAINT MIXING ROOMS

 

The paint mixing process involves the use of flammable and hazardous materials that can create explosive atmospheres, health risks and significant fire loading. Hazards include:

 

  • Release of flammable solvent vapours.

  • Ignition from electrical equipment.

  • Static discharge during transfer and mixing.

  • Spills leading to fire spread.

  • Exposure to solvents and isocyanates.

  • Storage of excessive quantities of paints, thinners and hardeners.

 

Appropriate design, ventilation, storage, housekeeping and operational controls are therefore essential to reduce the likelihood of fire, explosion, environmental contamination and employee injury. Controls include:

 

  • Dedicated paint-mixing room separated from production areas.

  • Non-combustible construction where practicable.

  • Mechanical extraction ventilation.

  • Suitable hazardous area classification.

  • Ex-rated electrical installations where required.

  • Bonding/earthing of containers during transfer.

  • Limited stock quantities maintained at point of use.

  • Storage of bulk flammable liquids within approved flammable liquid cabinets or stores.

  • Spill kits and documented spill-response procedures.

  • COSHH assessments for all paints, hardeners, lacquers and solvents.

 

PAINT SPRAY BOOTHS

 

The primary purpose of a spray booth is to:

 

  • Contain overspray.

  • Control the spread of flammable vapours.

  • Protect operators from exposure to hazardous substances.

  • Prevent contamination of surrounding work areas.

  • Reduce the likelihood of fire and explosion.

  • Provide controlled drying and curing conditions.

 

A spray booth should be regarded as an engineered safety system, not merely a workspace.

 

PRINCIPAL HAZARDS

 

Flammable Vapour Formation

 

Paints, lacquers, thinners and cleaning solvents release combustible vapours during application and drying. Spraying significantly increases the surface area of the liquid, accelerating solvent evaporation and increasing the likelihood of a flammable atmosphere developing.

 

Potential consequences include:

 

  • Flash fire

  • Explosion

  • Rapid fire development

  • Extensive smoke damage


Lacquer Application

 

Automotive clear coats and lacquers typically contain:

 

  • Acetone

  • Xylene

  • Toluene

  • Ethyl acetate

  • Polyurethane resins

  • Isocyanate hardeners

 

The application of lacquers frequently represents the highest fire and health risk, with hazards including:

 

  • High vapour generation

  • Flammable solvent release

  • Isocyanate exposure

  • Exothermic curing reactions

  • Contaminated waste accumulation

 

Isocyanate Exposure

 

Many 2K lacquer and clear coat systems contain isocyanates. Exposure may occur through:

 

  • Inhalation

  • Skin absorption

  • Contaminated clothing

 

Health effects include:

  • Occupational asthma

  • Respiratory sensitisation

  • Chronic respiratory disease

 

Once sensitised, workers may react to extremely low future exposures.

For this reason, positive-pressure air-fed breathing apparatus should be used when spraying isocyanate-containing paints and lacquers.

 

Overspray Deposits

 

Paint and lacquer particles accumulate on:

 

  • Booth walls

  • Lighting units

  • Extraction plenums

  • Filters

  • Ductwork

 

Overspray residue constitutes a combustible fuel source and can support significant fire spread.

 

Static Electricity

 

Static electricity may be generated by:

 

  • Atomisation processes

  • Air movement

  • Paint transfer systems

  • Vehicle surfaces

    • An electrostatic discharge may ignite solvent vapours.

 

Controls should include:

 

  • Earthing

  • Bonding

  • Anti-static footwear

  • Grounded spray equipment

 

SPRAY BOOTH CONSTRUCTION REQUIREMENTS

 

Booth Construction

 

Spray booths should be constructed from non-combustible materials. The following should be avoided:

 

  • Timber construction

  • Combustible linings

  • Composite panels containing combustible insulation

 

Location

 

Where practical, spray booths should:

 

  • Be separated from production areas.

  • Be located against an external wall.

  • Not be installed below ground level.

  • Allow direct discharge of extracted air to atmosphere.

 

High-value or high-throughput operations may warrant dedicated fire-resisting spray areas.

 

Booth Layout

 

Booths should be designed to:

 

  • Promote uniform airflow.

  • Eliminate stagnant areas.

  • Prevent overspray accumulation.

  • Facilitate cleaning and maintenance.

 

Surfaces should be smooth and easy to clean.

 

VENTILATION REQUIREMENTS

 

General

 

Ventilation is the most important safeguard against vapour accumulation. Its purpose is to:

 

  • Maintain solvent concentrations well below flammable limits.

  • Protect worker health.

  • Remove overspray.

  • Support drying processes.

 

Best practice is to design ventilation systems so flammable vapours remain below 25% of the Lower Explosive Limit (LEL).

 

Interlocks

 

Spraying equipment should not operate unless ventilation is proven operational.

Recommended interlocks include:

 

  • Airflow switches

  • Differential pressure monitoring

  • Fan running status monitoring

 

Exhaust Systems

 

Exhaust systems should:

 

  • Discharge externally.

  • Be independent where possible.

  • Minimise bends and restrictions.

  • Prevent recirculation of contaminated air.

 

Air intakes should be positioned so that extracted solvent vapours cannot re-enter the building.

 

Clearance Time

 

Spray booth clearance times should be established, displayed and observed before operators remove respiratory protection or enter the booth following spraying.

 

Spray Booth Performance Verification

 

Spray booths should be commissioned, tested and maintained to ensure effective control of vapours and overspray. Airflow performance, pressure monitoring, filter condition and clearance times should be verified and documented. Any deterioration in performance should be investigated and corrected before spraying activities continue.

 

DRYING & BAKING HAZARDS

 

Overview

 

The drying phase is frequently overlooked but remains a critical fire risk. Fresh coatings continue releasing flammable vapours during:

 

  • Flash-off periods

  • Heated bake cycles

  • Infrared curing

 

The highest risk often occurs when heat is introduced while solvents continue evaporating.

 

Heated Booths

 

Most automotive booths utilise:

 

  • Gas-fired burners

  • Diesel-fired heaters

  • Electric heaters

  • Infrared systems

 

Hazards include:

 

  • Ignition of solvent vapours

  • Equipment malfunction

  • Overheating

  • Fire spread

 

Booth heating systems should be interlocked with extraction systems.

 

Combination Spray/Bake Booths

 

Combination spray and bake booths are common within body shops. Safe operation requires:

 

  • Spraying and heating systems to be interlocked.

  • Heating to be disabled during spraying.

  • High temperature cut-outs.

  • Temperature monitoring systems.

  • Automatic shutdown arrangements.

 

Drying systems should be fitted with independent high-temperature cut-outs in accordance with the manufacturer's recommendations and recognised standards.

 

Infrared Drying Equipment

 

IR systems should:

 

  • Be maintained in accordance with manufacturer instructions.

  • Be positioned clear of combustibles.

  • Never be left operating unattended.

  • Be inspected regularly for damage.

 

No matter the type of baking/drying used, it should never be an unattended process (out of business hours) unless agreed/approved by the insurance company.

 

FIRE PROTECTION

 

Automatic Fire Detection

 

Automatic fire detection should be provided within:

 

  • Spray booths

  • Mixing rooms

  • Drying areas

  • Solvent stores

 

Connection to a monitored alarm receiving centre is recommended.

 

Sprinkler Protection

 

It is strongly recommended to have automatic sprinkler protection within spray booths and associated spray areas. The LPC Rules for Automatic Sprinkler Installations incorporating BS EN 12845 classifies paint spray booths and associated process areas as High Hazard Process (HHP). Protection should include:

 

  • The spray booth itself

  • Booth plenums

  • Extract chambers

  • Concealed combustible spaces

  • Areas above booths

 

Special arrangements may be required to prevent overspray contamination of sprinkler heads.

 

Portable Fire Extinguishers

 

Suitable extinguishers should be readily accessible, including:

 

  • Foam

  • CO₂

  • Dry powder (where appropriate)

 

Personnel should receive training in their use.

 

Ignition Source Control

 

The following should be prohibited within spray booth areas:

 

  • Smoking

  • Naked flames

  • Portable heaters

  • Hot work

  • Non-approved electrical equipment

 

Surfaces within hazardous areas should not present an effective ignition source for the materials in use.

 

HOUSEKEEPING

 

Poor housekeeping remains a common cause of spray painting fires. Control measures should include:

 

  • Metal waste containers with metal lids for disposing of contaminated wipes/rags within process areas.

  • Removal of contaminated wipes/rags and all combustible waste to external dedicated storage containers at the end of each day.

  • Segregation of hazardous waste streams.

  • Scheduled disposal arrangements.

  • Prevention of residue accumulation on all surfaces and within extraction systems. Deposits on any surface should not exceed approximately 3 mm in thickness, and corrective maintenance should be undertaken if overspray accumulation becomes excessive.

 

A formal cleaning programme should include:

 

Daily

  • Booth floors

  • Waste containers

  • Mixing areas

 

Weekly

  • Filters

  • Lighting assemblies

  • Extraction chambers

 

Monthly

  • Ductwork inspection

  • Fan inspection

  • Plenum inspection

 

MAINTENANCE & TESTING

 

A documented maintenance programme should include:

 

Daily

  • Airflow checks

  • Housekeeping inspections

  • Equipment condition checks

 

Weekly

  • Earthing verification

  • Filter inspections

  • Waste management inspections

 

Monthly

  • Ventilation testing

  • Fire protection inspections

  • Ductwork inspection

 

Annually

  • Thorough examination of ventilation systems (at interval not exceeding 14 months)

  • DSEAR review

  • Interlock testing

  • Heating system servicing

 

 

CONCLUSION

 

Automotive paint spraying operations present significant fire, explosion and occupational health hazards arising from the use of flammable liquids, combustible residues and hazardous substances such as isocyanates. Effective risk control requires a combination of engineering controls, management systems and safe working practices.

 

Particular attention should be given to the design and operation of spray booths, ventilation performance, hazardous area classification, housekeeping, fire protection systems and the safe handling and storage of paints, solvents, lacquers and waste materials. Ancillary activities including paint mixing and material storage should be subject to the same level of risk assessment and control as the spraying operation itself.

 

Facilities should operate in accordance with applicable legislation, including DSEAR and COSHH, and should adopt recognised industry guidance and standards for spray booths, drying equipment and potentially explosive atmospheres. Regular inspection, maintenance and testing of ventilation systems, fire protection systems and safety interlocks are essential to ensure continuing effectiveness.

 

Where the controls outlined in this bulletin are implemented and maintained, the likelihood of fire, explosion and harmful employee exposure can be significantly reduced, resulting in safer operations, improved resilience and reduced property and business interruption losses.

 

REFERENCES

 

The Dangerous Substances and Explosive Atmospheres Regulations 2002 (DSEAR). Health and Safety Executive.

 

Control of Substances Hazardous to Health Regulations 2002 (COSHH).

 

Regulatory Reform (Fire Safety) Order 2005 and equivalent fire safety legislation in Scotland and Northern Ireland.

 

HSG276: Isocyanate Paint Spraying - Safely Managing Spray Booths and Rooms, Health and Safety Executive.

 

HSG261: Health and Safety in Motor Vehicle Repair and Associated Industries, Health and Safety Executive.

 

BS EN 16985:2018 - Spray Booths for Organic Coating Material. Safety Requirements. This standard supersedes earlier booth standards and represents current good practice for spray booth safety.

 

EN 1539 - Dryers and Ovens in Which Flammable Substances are Released. Safety Requirements.

 

BS EN 60079 Series - Explosive Atmospheres, including inspection and maintenance requirements for hazardous area electrical installations.

 

LPC Rules for Automatic Sprinkler Installations Incorporating BS EN 12845.

 

HSE Guidance on Electrical Equipment in Potentially Explosive Atmospheres.

bottom of page